NEXG Apparels is one of the leading Manufacturer, Supplier and Exporter of IS Approved Fire Suit.

NEXG Apparels make IS Approved Fire Suit is a specialized personal protective garment manufactured and designed to protect firefighters, emergency responders, industrial workers, and rescue personnel from intense heat, flames, radiant heat, and thermal exposure encountered during firefighting and high-temperature operations. Manufactured using heat-resistant and flame-retardant materials, the suit provides a protective barrier between the wearer and hazardous thermal environments.

The fire suit is designed and tested in accordance with the applicable Indian Standard (IS) requirements, with its exact certification depending on the type and configuration of the protective clothing. It generally consists of a protective jacket, trousers, helmet, gloves, safety footwear, and other compatible protective accessories, depending on the required level of protection.

The multi-layer construction helps reduce heat transfer while allowing the wearer to carry out firefighting, rescue, inspection, and emergency-response activities with greater safety and mobility. Ergonomic design, secure closures, reinforced areas, and heat-resistant components contribute to improved durability and wearer protection.

NEXG Apparels - IS Approved Fire Suit Technical Specification :

Compliance & Standards : The fire suit is manufactured and tested in accordance with applicable Indian and International standards:

  • IS 16890:2018 - Protective Clothing for Firefighters
  • IS 11871 - Vertical Flammability Test for Flame Resistant Textiles
  • EN 469:2020 - Protective Clothing for Firefighting
  • EN ISO 11612 - Protection against Heat and Flame
  • EN 1149 - Antistatic Properties
  • EN ISO 13688 - General Requirements for Protective Clothing
  • SOLAS / Marine Safety Compliance (Optional)

Construction : The suit provides excellent protection against radiant heat, convective heat, molten splash, flame spread and static electricity.

Technical Specification :

Component Specification
Outer Shell 93% Meta-Aramid, 5% Para-Aramid, 2% Antistatic Fibre
Moisture Barrier PTFE Aramid Non-Woven Membrane
Thermal Barrier FR Non-Woven Quilted with FR Fabric
Lining Flame Resistant Fabric
Thread Para-Aramid Flame Resistant Thread
Reflective Tape High Visibility FR Reflective Tape
Number of Layers 3 Layer / 4 Layer Construction

Design Features :

  1. Jacket : Front heavy-duty FR zipper with storm flap
    • High collar for neck protection
    • Adjustable cuffs
    • Radio pocket and utility pockets
    • Retro-reflective tapes on chest, sleeves and back
  2. Trouser : High-waist design
    • Adjustable suspenders
    • Reinforced knee area
    • Adjustable ankle closure
  3. Hood : Compatible with breathing apparatus
    • Heat-resistant face shield or visor option
  4. Gloves : Flame resistant gloves conforming to EN 659
  5. Boots : Heat resistant rubber/fireman boots
    • Slip-resistant sole
  6. Fabric Weight : 450 - 700 GSM
  7. Suit Weight : 6.5 - 9.5 Kg
  8. Colour Options : Navy Blue, Orange, Red, Khaki, Silver
  9. Sizes : S, M, L, XL, XXL, Custom Sizes

Heat Resistance Performance :

Performance values vary depending on suit type and layer construction.

Parameter Performance
Flame Resistance Permanent/Inherent
Radiant Heat Protection Up to 1600°C (Aluminized Suit)
Ambient Heat Protection Up to 800°C
Direct Flame Exposure Up to 1000°C
Antistatic Property Available

Applications industries :

IS Approved Fire Suits are commonly used in :

  • Fire & Rescue Departments
  • Refineries and Petrochemical Plants
  • Oil & Gas Industries
  • Chemical and Pharmaceutical Industries
  • Steel and Metal Industries
  • Power Plants
  • Manufacturing Industries
  • Warehouses and Industrial Facilities
  • Emergency Response Teams
  • High-Temperature Industrial Operations

For critical fire safety operations, NEXG Fire Suits provide certified protection against heat, flame, molten splash and hazardous environments while meeting IS and international safety requirements.

FAQs for NEXG Apparels make IS Approved Fire Suit :

A1: An IS Approved Fire Suit is protective clothing designed for firefighters and emergency-response personnel to provide protection against intense heat, flame, radiant heat and other hazards encountered during firefighting operations. NEXG Apparels manufactures fire suits designed to meet applicable Indian Standard requirements for firefighter protective clothing.

A2: Yes. The suit is designed for professional firefighting applications where personnel may be exposed to high heat, flame and other thermal hazards, subject to the certified configuration and intended use

A3: Yes. Protective firefighter clothing is designed and tested for thermal protection, including protection against radiant heat, in accordance with the applicable performance requirements of the relevant standard.

A4: NEXG Fire Suits are designed with ergonomic construction and multilayer protective system to balance thermal protection, mobility and wearer comfort. Proper sizing is important for achieving optimum movement and comfort.

A5: The suit is designed to provide adequate freedom of movement required for firefighting activities such as climbing, crawling, handling hoses and operating firefighting equipment, while maintaining the required protective coverage

A6: These fire suits can be used by municipal fire brigades, industrial fire departments, chemical and petrochemical plants, oil & gas facilities, manufacturing industries, airports, power plants, refineries and emergency-response teams, subject to the specific application requirements.

A7: The suit provides thermal and flame protection as specified by its applicable certification. However, protection against specific chemicals should not be assumed unless the particular suit has been tested and certified for the relevant chemical hazards.

A8: Depending on the certified product configuration and order requirements, NEXG Apparels can offer suitable options for sizing, identification markings and other permissible specifications. Any modification affecting certified performance should be evaluated for compliance.

A9: The suit should be inspected before and after use, and more thoroughly at regular intervals. Any signs of burning, tearing, contamination, damaged closures, worn protective layers or other deterioration should be assessed before the suit is returned to service.

A10: Fire departments, industrial organization’s, factories, refineries, petrochemical companies, power plants, airports, emergency-response teams and other organization’s requiring certified firefighter PPE can procure suitable IS-compliant fire suits.

A11: NEXG Apparels focuses on manufacturing and supplying specialized protective apparel for demanding industrial and firefighting applications. The company provides fire-resistant protective products designed around applicable Indian and international safety requirements.