NEXG Apparels make IS Approved Fire Suit is a specialized personal protective garment manufactured and designed to protect firefighters, emergency responders, industrial workers, and rescue personnel from intense heat, flames, radiant heat, and thermal exposure encountered during firefighting and high-temperature operations. Manufactured using heat-resistant and flame-retardant materials, the suit provides a protective barrier between the wearer and hazardous thermal environments.
The fire suit is designed and tested in accordance with the applicable Indian Standard (IS) requirements, with its exact certification depending on the type and configuration of the protective clothing. It generally consists of a protective jacket, trousers, helmet, gloves, safety footwear, and other compatible protective accessories, depending on the required level of protection.
The multi-layer construction helps reduce heat transfer while allowing the wearer to carry out firefighting, rescue, inspection, and emergency-response activities with greater safety and mobility. Ergonomic design, secure closures, reinforced areas, and heat-resistant components contribute to improved durability and wearer protection.
Compliance & Standards : The fire suit is manufactured and tested in accordance with applicable Indian and International standards:
Construction : The suit provides excellent protection against radiant heat, convective heat, molten splash, flame spread and static electricity.
| Component | Specification |
|---|---|
| Outer Shell | 93% Meta-Aramid, 5% Para-Aramid, 2% Antistatic Fibre |
| Moisture Barrier | PTFE Aramid Non-Woven Membrane |
| Thermal Barrier | FR Non-Woven Quilted with FR Fabric |
| Lining | Flame Resistant Fabric |
| Thread | Para-Aramid Flame Resistant Thread |
| Reflective Tape | High Visibility FR Reflective Tape |
| Number of Layers | 3 Layer / 4 Layer Construction |
Performance values vary depending on suit type and layer construction.
| Parameter | Performance |
|---|---|
| Flame Resistance | Permanent/Inherent |
| Radiant Heat Protection | Up to 1600°C (Aluminized Suit) |
| Ambient Heat Protection | Up to 800°C |
| Direct Flame Exposure | Up to 1000°C |
| Antistatic Property | Available |
IS Approved Fire Suits are commonly used in :
For critical fire safety operations, NEXG Fire Suits provide certified protection against heat, flame, molten splash and hazardous environments while meeting IS and international safety requirements.
A1: An IS Approved Fire Suit is protective clothing designed for firefighters and emergency-response personnel to provide protection against intense heat, flame, radiant heat and other hazards encountered during firefighting operations. NEXG Apparels manufactures fire suits designed to meet applicable Indian Standard requirements for firefighter protective clothing.
A2: Yes. The suit is designed for professional firefighting applications where personnel may be exposed to high heat, flame and other thermal hazards, subject to the certified configuration and intended use
A3: Yes. Protective firefighter clothing is designed and tested for thermal protection, including protection against radiant heat, in accordance with the applicable performance requirements of the relevant standard.
A4: NEXG Fire Suits are designed with ergonomic construction and multilayer protective system to balance thermal protection, mobility and wearer comfort. Proper sizing is important for achieving optimum movement and comfort.
A5: The suit is designed to provide adequate freedom of movement required for firefighting activities such as climbing, crawling, handling hoses and operating firefighting equipment, while maintaining the required protective coverage
A6: These fire suits can be used by municipal fire brigades, industrial fire departments, chemical and petrochemical plants, oil & gas facilities, manufacturing industries, airports, power plants, refineries and emergency-response teams, subject to the specific application requirements.
A7: The suit provides thermal and flame protection as specified by its applicable certification. However, protection against specific chemicals should not be assumed unless the particular suit has been tested and certified for the relevant chemical hazards.
A8: Depending on the certified product configuration and order requirements, NEXG Apparels can offer suitable options for sizing, identification markings and other permissible specifications. Any modification affecting certified performance should be evaluated for compliance.
A9: The suit should be inspected before and after use, and more thoroughly at regular intervals. Any signs of burning, tearing, contamination, damaged closures, worn protective layers or other deterioration should be assessed before the suit is returned to service.
A10: Fire departments, industrial organization’s, factories, refineries, petrochemical companies, power plants, airports, emergency-response teams and other organization’s requiring certified firefighter PPE can procure suitable IS-compliant fire suits.
A11: NEXG Apparels focuses on manufacturing and supplying specialized protective apparel for demanding industrial and firefighting applications. The company provides fire-resistant protective products designed around applicable Indian and international safety requirements.